Print Back
Kaeser Automatic Magnetic Drains (AMD) remove condensate and other contaminants from your air system. The large capacity of automatic magnetic drains makes them suitable for a broad range of applications. Highly dependable and requiring little maintenance, automatic magnetic drains maintain a "liquid seal" which prevents compressed air loss. Unlike traditional float drains, the operating mechanisms are isolated from condensate so no fouling or sticking occurs.
Unit of Measure

Specifications

Brands

N/A Kaeser Compressors

Model

N/A AMD 6550

Capacity

N/A 125 gal/h
Working Pressure1 N/A 60 to 225 psig

Maximum Working Temperature

N/A 200 ºF

Inlet Connection Size

N/A 3/4 in

Inlet Connection Type

N/A National Pipe Thread Female (NPT (F))

Outlet Connection Size

N/A 1/2 in

Outlet Connection Type

N/A National Pipe Thread Female (NPT (F))

Equalizing Line Size

N/A 1/2 in

Equalizing Line Type

N/A National Pipe Thread Female (NPT(F))

Weight

N/A 14 lb

Housing

N/A High tensile corrosion resistant aluminum.

Internals

N/A Stainless steel

Tubing

N/A Copper

External Fittings

N/A Brass Stainless Steel

Discharge Valve

N/A Brass

Seals

N/A Fluorocarbon (FKM) Nitrile Polytetrafluoroethylene (PTFE)

Applications

Applications

N/A Aftercoolers Coalescing Filter Drip Legs Liquid Separators Low-point Piping Receiver Tanks

Features

Features

N/A
  • High capacity
  • No air loss
  • All metal construction
  • Corrosion-resistant housings and internal parts
  • Mechanism separate from condensate reservoir
  • No electricity required
  • Test button
  • Visual indicator
  • Top or bottom connection

Note

Note

N/A Specifications are subject to change without notice.

High pressure versions available: Eco-Drain 12 for 913 psig MAWP and Eco-Drain 13 for 362 psig MAWP
  • 1 For operating pressures less than 60 psig, a source of pilot air of 60 to 225 psig must be supplied for cylinder operation. Fluorocarbon (FKM) and PTFE are registered trademarks of DuPont Corporation.